polypropylene depth cartridges

    Product Description

    Duo-PLEAT and Duo-MAXX depth over membrane cartridges combine a prefiltration layer with a final membrane layer in one pleated element. Designed as pre-final filters, the dual-layer configuration helps protect downstream final filters during critical process filtration.

    Available configurations pair a borosilicate microglass or polypropylene microfiber prefilter with polyethersulfone, polysulfone, or nylon final membrane media. Absolute-rated retention options range from 0.03 to 1.2 micron, depending on the selected membrane.

    Thermally bonded construction eliminates adhesives and binders, while non-fiber-releasing media and a high-strength design support extended service and multiple autoclave cycles.

    Features


    • Depth prefiltration and final membrane filtration in one cartridge
    • Absolute-rated membrane retention from 0.03 to 1.2 micron, by membrane type
    • Borosilicate microglass or polypropylene microfiber prefilter options
    • Polyethersulfone, polysulfone, and nylon membrane options
    • Thermally bonded construction without adhesives or binders
    • No additives or glue
    • Non-fiber-releasing media
    • High-strength construction for extended use and multi-autoclave cycles
    • Materials of construction stated as FDA compliant with CFR Title 21

    Technical Specifications


    • Filter Configuration: Depth prefilter over final membrane
    • Prefilter Media: Borosilicate microglass or polypropylene microfiber
    • Final Membrane Media: Polyethersulfone, polysulfone, or nylon
    • Retention Rating: Absolute rated
    • Outside Diameter: Duo-PLEAT: 2.55 in (64.8 mm); Duo-MAXX: 2.7 in (68.6 mm)
    • Lengths: 5, 10, 20, 30, and 40 in
    • Pleat Support: Polypropylene or polyester
    • End Configurations: Double open end; 213/recessed cup; 222 flat; single open end/flat; 222 recessed cup; 226 flat; 226 fin; 222 fin
    • Seal Materials: Buna N, fluorocarbon, EPDM, silicone, PTFE foam, PTFE hard, FEP-encapsulated fluorocarbon, FEP-encapsulated silicone
    • Maximum Differential Pressure: 75 psid at 75 F forward; 40 psid at 180 F forward; 50 psid at 75 F reverse
    • Maximum Operating Temperature: 180 F (82 C) continuous duty
    • Sterilization: Steam or autoclave; up to 20 cycles at 275 F (135 C)
    • Construction Method: Thermal bond
    • Compliance: USP Class VI and CFR 21 food-contact statement on supplied sheet

    Applications


    Use Duo-PLEAT and Duo-MAXX cartridges where upstream depth filtration and final membrane retention are needed in one element.

    • Biopharmaceutical processing
    • Bioburden reduction
    • Viscous fluids and viscous polymers
    • Pre-final filtration and prefiltration
    • Ultrapure water
    • High-purity chemical filtration