Product Description
Glass-PLEAT G and Fiber-MAXX G microglass depth filter cartridges are nominally rated liquid filter elements using non-calendered borosilicate microglass media. Their uniform, high-surface-area, high-void-volume matrix is designed to optimize pore-size geometry, flow rate, and service life.
Available in 0.2 to 10 micron retention ratings, these thermally bonded cartridges provide beta-rated media, low pressure drop, and non-fiber-releasing construction. Glass-PLEAT G has a 2.55 in outside diameter, while Fiber-MAXX G has a 2.7 in outside diameter.
FDA-grade cartridges meet or exceed 21 CFR 177 requirements for food and beverage contact. For General and Pharmaceutical Fiber-MAXX G grades, the optional Special Pleat geometry is expected to increase surface area by as much as 45%.
Features
- Beta-rated media supports reliable pore-size control and repeatable filtration.
- Non-fiber-releasing materials with minimal extractables support high-purity filtrate.
- High surface area and void volume help reduce resistance to flow.
- Thermally bonded construction eliminates particle bypass.
- Industrial-grade cartridges use an epoxy binder; FDA-grade cartridges use an acrylic binder.
- Fiber-MAXX G Special Pleat option provides optimized pleat geometry for General and Pharmaceutical grades.
Technical Specifications
- Micron ratings: 0.2, 0.45, 0.65, 1, 5, 10 micron nominal
- Filter media: Borosilicate microglass
- Pleat support: Polypropylene or polyester
- End caps and cage: Polypropylene or polyester
- Construction: Thermal bond
- Outside diameter: Glass-PLEAT G: 2.55 in (65 mm); Fiber-MAXX G: 2.7 in (70 mm)
- Lengths: 5, 10, 20, 30, 40 in
- Maximum differential pressure, forward flow: 75 psid (5.1 bar) at 75°F (24°C); 40 psid (2.8 bar) at 180°F (82°C)
- Maximum continuous operating temperature: 180°F (82°C) with polypropylene; 275°F (135°C) with polyester
- Gasket/O-ring materials: Silicone, Buna-N, fluorocarbon, EPDM, PTFE foam, PTFE hard, encapsulated fluorocarbon, encapsulated silicone
- End configurations: Double open end, 213/recessed cup, flat/222, single open end/flat, recessed cup/222, flat/226, fin/226, fin/222
- Options: 316 stainless steel insert, DI flush, all-polyester hardware
- Compliance: FDA-grade cartridges meet or exceed 21 CFR 177 requirements for food and beverage contact
Applications
- Inks and coatings
- Plating solutions
- Solvent filtration
- Wastewater
- Chemical processing
- Photographic films
- Oil and gas production
- Beer and wine filtration
Specifications
| Micron Ratings | 0.2, 0.45, 0.65, 1, 5, 10 micron |
|---|---|
| Rating Type | Nominal |
| Filter Media | Borosilicate microglass |
| Pleat Support | Polypropylene, polyester |
| End Caps | Polypropylene, polyester |
| Cage | Polypropylene, polyester |
| Binder | Epoxy for Industrial grade, acrylic for FDA grade |
| Construction Method | Thermal bond |
| Outside Diameter | Glass-PLEAT G: 2.55 in (65 mm), Fiber-MAXX G: 2.7 in (70 mm) |
| Lengths | 5, 10, 20, 30, 40 in |
| Maximum Differential Pressure | 75 psid (5.1 bar) at 75°F (24°C), forward flow; 40 psid (2.8 bar) at 180°F (82°C), forward flow |
| Maximum Operating Temperature | 180°F (82°C) continuous with polypropylene, 275°F (135°C) continuous with polyester |
| Gasket/O-Ring Materials | Silicone, Buna-N, fluorocarbon, EPDM, PTFE foam, PTFE hard, encapsulated fluorocarbon, encapsulated silicone |
| End Configurations | Double open end, 213/recessed cup, flat/222, single open end/flat, recessed cup/222, flat/226, fin/226, fin/222 |
| Cartridge Options | 316 stainless steel insert, DI flush, all-polyester hardware |
| Special Pleat Option | Fiber-MAXX G; expected surface-area improvement of as much as 45% for General and Pharmaceutical grades |
| Food Contact Compliance | FDA-grade cartridges meet or exceed 21 CFR 177 requirements for food and beverage contact |